App Intel

FireOps Engineer

LiveEMSCodeSim5 apps · 1.2K installsEducationFreecom.fireopscalc.engineer

Fire pump pressure calculator and fireground tools for engineers and firefighter

Alert me★ WatchOpen in Play ↗
Total installs
17
exact · Play shows 10+
Installs / day
0
since last crawl
Rating
—★
— ratings · — reviews
Released
14 Aug 2026
2mo ago
Last update
25 Sept 2026
v1.2.4 · 17d ago
Countries
—
not checked yet

Install history

exact counter from Google Play
16.617.518.319.22010 Oct12 Oct13 Oct
16.617.518.319.22010 Oct12 Oct13 Oct

Installs per day · last 90 days

00.30.50.8111 Oct12 Oct13 Oct

Change timeline

Full history

No changes recorded yet. We compare every crawl with the previous one and list title, icon, screenshots, description, version, price and availability changes here.

Country availability

Availability has not been checked for this app yet. “Check all countries” looks the app up in about 140 Google Play storefronts and shows where it is live, listed but not installable, or missing — plus any country-specific (custom) store listings.

Top countries

Country data will be available soon.

We estimate where downloads come from using the app’s position in Google Play’s top charts in about 140 countries. This app is not in any chart we have collected yet; the estimate appears as soon as it is.

Top chart positions

Not in any tracked top chart.

App manifest

Read this app's manifest from Google Play: permissions, declared SDKs, components and AdMob app ID. Saved analysis appears here automatically.

Manifest analysis reads only the required APK ranges. Base APK downloads may need separate device splits to install.

Data safety

declared by the developer on Google Play
  • No data shared with third parties
  • No data collected

This is the developer's own declaration, summarised from the Play listing. The permissions below show what the app is technically able to access.

Permissions

2 in 1 group
0 Sensitive0 Notable2 Routine
OtherRoutine2

Access to miscellaneous device features that don't fit other categories

  • Connect to the internet to load content and send datafull network access · INTERNET
  • Check with Google Play that you got this app legitimatelyGoogle Play license check · com.android.vending.CHECK_LICENSE

Sensitive = can reach personal data, location, camera/mic or act on your behalf. Notable = changes how your device behaves. Routine = normal for almost every app. Source: Google Play's permission list for all versions of this app.

Store listing

Full description
FireOps Engineer is a fire pump pressure calculator and fireground reference tool for apparatus engineers, driver/operators, pump operators, firefighters, instructors, and fire academy students. The app simplifies common fire service hydraulic calculations by allowing users to build hose layouts using hose length, diameter, flow, nozzle pressure, appliances, and elevation. Use FireOps Engineer for pump training, apparatus drills, promotional exam preparation, classroom instruction, and pre-incident planning. PUMP PRESSURE CALCULATOR Build common hose layouts and calculate estimated pump discharge pressure. Calculations may include: • Friction loss • Hose length and diameter • Water flow • Nozzle pressure • Elevation pressure • Appliance loss • Wyes and branched lines • Multiple attack lines • Standpipe operations • Master streams MULTIPLE HOSE LINES Create and compare multiple hose lines operating from the same apparatus. Each line can have its own hose length, diameter, nozzle, flow, elevation, and appliance setup. FireOps Engineer helps identify the line with the greatest pressure requirement. WYE AND BRANCHED OPERATIONS Create layouts using gated wyes and divided hose lines. Configure each branch with different hose lengths, nozzles, flows, and pressure requirements. Use these tools to practice residential, apartment, commercial, extended-stretch, leader-line, backup-line, and wildland operations. MASTER STREAM TOOLS Review deck gun and portable monitor operations. Estimate flow, nozzle pressure, friction loss, and pump discharge pressure for high-flow operations. STANDPIPE AND FDC OPERATIONS Estimate pump pressure for standpipe, sprinkler, and fire department connection operations. Account for hose friction loss, floor elevation, nozzle pressure, and appliance loss. FIREGROUND TOOLS Additional tools may include: • Friction loss • Nozzle reaction • Hydrant flow • Relay pumping • Standpipe pressure • Sprinkler and FDC pressure • Foam operations • Tender or tanker shuttle planning • Master stream calculations • Solid-bore nozzle calculations • Elevation pressure • Rural water supply DEPARTMENT SETUP Customize FireOps Engineer around the equipment and operating practices used by your department. Configure hose sizes, coefficients, preconnected hose lengths, fog and smooth-bore nozzles, nozzle flows, nozzle pressures, apparatus names, and department notes. DIGITAL PUMP CARD Keep frequently used hose, nozzle, flow, and pressure information available in one place. Review common preconnects, friction loss information, smooth-bore nozzle data, apparatus notes, and department references. BUILT FOR TRAINING Use FireOps Engineer for: • Driver/operator training • Engineer promotional preparation • Fire academy instruction • Company drills • Apparatus familiarization • Instructor demonstrations • Fireground simulations • Hydraulic calculation practice • Reviewing pump charts • Pre-incident planning FireOps Engineer is designed to make pump calculations easier to understand. IMPORTANT SAFETY NOTICE FireOps Engineer is intended for training, education, planning, and reference purposes. Calculations are estimates and may not account for every condition present during an emergency. Always follow your department’s standard operating procedures, approved pump charts, manufacturer instructions, local policies, training, and incident command direction. Pump operators must monitor intake and discharge pressures, confirm adequate water supply and fire flow, observe hose and appliance limitations, and adjust operations based on actual fireground conditions. FireOps Engineer is not affiliated with or endorsed by any fire department, apparatus manufacturer, equipment manufacturer, standards organization, or government agency.

Growing in Education

Category →